The solenoid valve adopts electric as signal, can work automatically or remote controlled. The automation controlling components of the medium pipe connection can open or close rapidly and easy to use with stable performances.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Main Specifications

    Valve Body Material Brass, Stainless Steel
    Interface Thread 1/8''--3'' Flange 1/2''--3''
    Working Pressure 0-10 kg (0-1.0 MPa)
    Flow Passage Ø2.5-65mm+
    Environmental Temperature -5°C+40°C
    Operating Temperature Rang -5°C--80°C / 150°C
    Voltage AC220V AC380V DC24V DC12V(Customized Available)
    Power DN08-10:10W DN15-32:12W DN40-65:15W
    Working Medium Liquid, Gas, Oil

     

    2W Series Two-way Two-position Diaphragm Solenoid Valve
    Picture 2W Series Solenoid Valve Instruction 6 2W Series Solenoid Valve Instruction 7
    Type Direct Action, Normally Closed Direct Action, Normally Closed
    Working Form Energized Open, De-energized Closed Energized Open, De-energized Closed
    Working situation Non-waterproof type Outdoor Waterproof type
    Character High cost effective Low energy Consumption, without overheating for long term work
    Installation Method Horizontal installation with the coil facing upwards, allowing an inclination of no more than 30° , with the medium flow direction consistent with the arrow on the solenoid valve.

    Model and Specification

    2W Series Solenoid Valve-Brass Valve Body Threaded Connection Specifications and Dimensions  
    Model Connecting thread G Flow Diameter(mm) Sealing Material Valve Body Length(mm) Valve Body Height(mm) NBR(Nitrile Rubber) ≤80℃
    2w08 1/4’’ 2.5 NBR/VITON 38mm 73
    2w10 3/8’’ 2.5 NBR/VITON 52mm 73
    2w15 1/2’’ 16 NBR/EPDM/VITON 64mm 107  
    2w20 3/4’’ 20 NBR/EPDM/VITON 66mm 111 EPDM (Ethylene Propylene Diene Monomer Rubber) ≤120℃ VITON(Fluor Rubber)≤150℃
    2w25 1’’ 25 NBR/EPDM/VITON 84mm 120
    2w32 11/4’’ 32 NBR/EPDM/VITON 100mm 134
    2w40 11/2’’ 40 NBR/EPDM/VITON 108mm 164
    2w50 2’’ 50 NBR/EPDM/VITON 130mm 176
    2w65 2.5’’ 58 NBR/VITON 178mm 204  
    2w80 3’’ 58 NBR/VITON 190mm 215  
    2W Series Solenoid Valve-Stainless Steel Body Thread Connection Specifications and Dimensions Flange Connection Specifications and Dimensions  
    Model Connecting thread G Flow Diameter (mm) Sealing Material Valve Body Length (mm) Valve Body Height(mm) Valve Body Length (mm) Valve Body Height (mm) NBR ≤80℃ EPDM ≤120℃ VITON ≤150℃
    2w10B 3/8’’ 10 NBR/EPDM/VITON 68 94 / /
    2w15B 1/2’’ 16 NBR/EPDM/VITON 68 94 107 146
    2w20B 3/4’’ 20 NBR/EPDM/VITON 72 101 107 158
    2w25B 1’’ 25 NBR/EPDM/VITON 98 108 138 160
    2w32B 11/4’’ 32 NBR/EPDM/VITON 111 139 148 200
    2w40B 11/2’ 40 NBR/EPDM/VITON 120 146 154 210
    2w50B 2’’ 50 NBR/VITON 166 162 185 230
    2w65B 2.5’’ 58 NBR/VITON 178 205 225 255
    2w80B 3’’ 80 NBR/VITON 220 220 273 257

    product details

    b1 (9)
    b1 (9)
    b2 (9)
    b2 (9)
    b5 (8)
    b5 (8)
    Solenoid Valve-20
    Solenoid Valve-20
    d3
    d3

    Attention of Set up and Usage

    2W Series Solenoid Valve Instruction 13 When setting, the direction of the medium should be as the same as the arrow direction of the valves. The valves should be set up only on horizontal pipes. The coils must be at a vertical position. The valves can not be set up in where splashes or leaks, except for the water proof type.

    2W Series Solenoid Valve Instruction 14 The pipes should be clean thoroughly. The medium should be pure with a viscosity < 4° E.

    2W Series Solenoid Valve Instruction 15 A filter of 80~ 100 mesh should be set up in front of the valve in order to prevent the stuck of the coils.

    A check should be setup at the back of the valve when the pressure if high to prevent the lax of shutting down or revering of the medium flow.

    2W Series Solenoid Valve Instruction 16 The valve and the residues on the suction surface of the medal core should be cleaned in time. Please check the sealing when disassembled. The broken parts should be changed in time.

    2W Series Solenoid Valve Instruction 17 The valves should not be used in dangerous environment of explosion. Please order the explosion proof type if you need.

    2W Series Solenoid Valve Instruction 18 The  bypass  devices should  be set  up to  make sure the  normal  usage.  It  can  help the  in time cleaning and changing when the valves faulty. (see following picture)

    2W Series Solenoid Valve Instruction 19 The power condition should be chose according to the name plate. The control relay should connect the lead wire of the valves into circuit. The valves should be installed grounding when set up the system to make the safety.

    图片3 (3)

    Application

    c5 (6)
    c5 (6)
    c4 (5)
    c4 (5)
    c3 (5)
    c3 (5)
    c2 (6)
    c2 (6)
    c1 (6)
    c1 (6)
    b4 (10)
    b4 (10)
    b3 (10)
    b3 (10)
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Hebei JIRS Import & Export Co., Ltd., we specialize in providing top-notch water quality analyzers and sensors that meet the diverse needs of our clients. 
    Contact: Sunnie Lee
    Tel: +86 13784354125
    WhatsApp: +86 13784354125
    Company Address: No.188, Fengshou Road, Chang'an district, Shijiazhuang City, Hebei China 050041
    Customer service
    detect