loading

Professional water quality analyzer designer and manufacturer - Hebei JIRS

Operating Manual for Metering Pump 1
Operating Manual for Metering Pump 2
Operating Manual for Metering Pump 3
Operating Manual for Metering Pump 4
Operating Manual for Metering Pump 5
Operating Manual for Metering Pump 6
Operating Manual for Metering Pump 7
Operating Manual for Metering Pump 1
Operating Manual for Metering Pump 2
Operating Manual for Metering Pump 3
Operating Manual for Metering Pump 4
Operating Manual for Metering Pump 5
Operating Manual for Metering Pump 6
Operating Manual for Metering Pump 7

Operating Manual for Metering Pump

This manual includes relevant information about installation, operation and maintenance instruction of electromagnetic diaphragm metering pump. Refer to the nameplate of the pump to confirm the actual model.

Protection grade of IP55
Antiseptic plastic shell
220VAC, 50 Hz: Standard power supply 220VAC, 50 Hz

Material Table of Metering Pump (the part contacting with the mediator)
Diaphragm: PTFE
Pump head: PVC, PP
One-way valve: PVC, PP
Valve ball: CERAMIC
Sealing element: FPM
Pipette: PVC, PE, PTFE
Outlet pipe: PE, PTFE
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    S Series Specification Parameter

    Model Flow (L/h) Pressure (bar) Stroke Frequency (times /min) Suction Height (m) Power (W) Power Weight (kg)
    -01-07-S 1 7 120 2 25 220V 50HZ 2.3
    -02-07-S 2 7 120 2 25 220V 50HZ 2.3
    -03-07-S 3 7 120 2 25 220V 50HZ 2.3
    -06-05-S 6 5 160 2 25 220V 50HZ 2.3
    -09-03-S 9 3 180 2 25 220V 50HZ 2.3

    Safety Notes

    In use of chemical mediator, basic safety precautions must be followed to reduce danger of fire hazard, electric shock and personal injury. Please read all the instruction.

    Operating Manual for Metering Pump 8 Don't transport flammable liquid.

    Operating Manual for Metering Pump 9 When you operate chemical metering pump or work near it, you must wear protective clothing, including gloves and safety goggles.

    Operating Manual for Metering Pump 10 Check the pipeline regularly to find out whether there is any fracture or aging. Replace the pipeline when it is necessary. (You must wear protective clothing and goggles when you check the pipeline.)

    Operating Manual for Metering Pump 11 Follow the instruction and warning information provided by the manufacturer of chemicals. The users are responsible for confirm the compatibility of the chemicals and the metering pump.

    Operating Manual for Metering Pump 12 Confirm whether the voltage on the nameplate of the metering pump is the same with the voltage of the device. If the pump can't be started, check the voltage of the pipeline.

    Operating Manual for Metering Pump 13 In treatment of drinking water, consult the local health officials and water treatment experts.

    Operating Manual for Metering Pump 14 You must reduce the pressure of the system before installing or disconnecting the pump pipeline.

    Operating Manual for Metering Pump 15 If the injection point is lower than the storage tank of chemicals and the pump, syphonage-proof valve should be installed.

    Operating Manual for Metering Pump 16 Don't modify the pump, because it will cause potential danger and make quality guarantee lose efficacy.

    Operating Manual for Metering Pump 17 Before leaving the factory, water transport test should be made for all pumps. If the transported chemicals react with water (for example, sulfuric acid), it needs to dismount the pipeline and dry it thoroughly.

    Operating Manual for Metering Pump 18 Before installation, consult the plumbers and electricians with certificates. Installation should conform to the local regulations.

    Operating Manual for Metering Pump 19 The metering pump must be calibrated in the working conditions to be used, in order to acquire accurate volume output.

    Operation Principle

    Electromagnetic diaphragm metering pump is the equipment used for transporting chemicals or liquid. When power of it is on, the electromagnetic coil generates magnetic field which makes the movement diaphragm of push rod deform. With the effect of check valve, the liquid is transported to the outlet under the pressure effect.

    When power of electromagnetic coil is off, the diaphragm is reset under the effect of the spring. The liquid will be sucked into the pump head. And one time of liquid transport is completed.

    undefined

    product details

    b1 (7)
    b1 (7)
    b2 (7)
    b2 (7)
    b3 (7)
    b3 (7)
    b4 (7)
    b4 (7)
    c1 (5)
    c1 (5)
    c2 (5)
    c2 (5)
    c3 (4)
    c3 (4)
    c4 (4)
    c4 (4)
    c5 (4)
    c5 (4)
    c6 (4)
    c6 (4)
    c7 (2)
    c7 (2)
    c8 (2)
    c8 (2)
    c9 (2)
    c9 (2)
    d3
    d3
    d1
    d1
    d2
    d2

    Application

    application1
    application1
    application2
    application2
    application3
    application3
    application4
    application4
    application5
    application5
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Hebei JIRS Import & Export Co., Ltd., we specialize in providing top-notch water quality analyzers and sensors that meet the diverse needs of our clients. 
    Contact: Sunnie Lee
    Tel: +86 13784354125
    WhatsApp: +86 13784354125
    Company Address: No.188, Fengshou Road, Chang'an district, Shijiazhuang City, Hebei China 050041
    Customer service
    detect